Performance and output

First year output estimator

Enter your system's full-year rated output and the month it was commissioned. See what your actual first calendar year is likely to produce.

Your system and commissioning date

1 Project details Optional
Shown on your exported report. Leave blank to skip.
2 Your system
What a complete, stabilized 12-month year would produce. Use the annual output estimator if needed.
The month your system was activated and began producing power.
3 Panel technology
Standard crystalline silicon panels typically see 1% to 3% LID in their first weeks of use.

Try a different LID rate

Drag the slider to change the light-induced degradation rate. The first-year output updates as you move it. Starting point is a system commissioned in April with 10,800 kWh a year and 2 percent LID, the same example as the tool above.

2%
First-year output
7,604 kWh
Share of a full year
70.8%
LID loss
46 kWh
0% LID
7,650 kWh
1% LID
7,627 kWh
2% LID
7,604 kWh
3% LID
7,581 kWh
4% LID
7,558 kWh
5% LID
7,535 kWh

Maths: an April start leaves 9 months, counted as 8.5 months of production, and light-induced degradation trims 30 percent of the LID figure in year one.

How it works

Two steps to your real first-year number

Step 1

Start with your full-year rated output

Use your system's stabilized annual output figure, or run the annual output estimator first if you don't have that number yet.

Step 2

Enter your commissioning month

This single input determines how many months of production your first calendar year actually captures. For a season-adjusted figure, check the monthly output estimator too.

Why an April start captures 71% of a full year

Hover or tap each part of the picture to see what it means.

SWITCHED ONApril 100%Full year 71%First year MONTHS CAPTURED9 of 12

Understanding your first year output

Why year one rarely matches your full annual figure

Unless a system is commissioned on January 1st, its first calendar year only captures partial months of production. A system turned on in April captures roughly 71% of a full year's output in that first calendar year, not the full annual figure. This is simple calendar math, not a sign of anything unusual about the system. A DOE study of federal PV systems found first-year performance can vary widely from modeled expectations, often due to start-up issues that resolve over time.

What light-induced degradation is and why it's a one-time event

Light-induced degradation is a small, one-time efficiency drop that occurs in a crystalline silicon panel's first weeks of sun exposure, typically 1% to 3%, after which the panel stabilizes at its rated output level. This mostly resolves within the first month or two of operation, so it has only a minor effect on the first year's total and essentially no effect on every year afterward. NLR's PV Lifetime Project tracks this kind of early-life behavior alongside longer-term degradation, and confirms that most of a panel's lifetime performance loss happens gradually over many years rather than in that initial stabilization period.

Why year two often looks better than year one

Often yes, simply because the second calendar year captures a full 12 months of production while the first year likely only captured a partial year from the commissioning date. This isn't a sign of anything wrong, just a full-year comparison versus a partial one. Comparing year one against a properly prorated expectation, not the full annual figure, is the fair comparison.

How commissioning season shapes the total

Yes. A system commissioned in late spring captures its remaining months during typically stronger summer production, while one commissioned in late fall captures mostly weaker winter months, so two systems commissioned the same number of months into the year can still see different first-year totals. The monthly output estimator can help refine this further based on your specific season. If you're still deciding on system size and want to weight that decision around your actual monthly usage pattern rather than a flat annual average, the system sizing by monthly usage tool takes that seasonal variation into account directly.

What to do with this number next

Once your system stabilizes past year one, track long-term performance with the year 10 and year 25 output estimators to see how gradual panel degradation plays out over the system's life. If you want to see what that figure means in dollars and years, the payback period calculator turns the same output figure into a timeline.

Questions

Frequently asked

Unless a system is commissioned on January 1st, its first calendar year only captures partial months of production. A system turned on in April captures roughly 71% of a full year's output in that first calendar year, not the full annual figure.

Light-induced degradation is a small, one-time efficiency drop that occurs in a crystalline silicon panel's first weeks of sun exposure, typically 1% to 3%, after which the panel stabilizes at its rated output level. This mostly resolves within the first month or two of operation.

Often yes, simply because the second calendar year captures a full 12 months of production while the first year likely only captured a partial year from the commissioning date. This isn't a sign of anything wrong, just a full-year comparison versus a partial one.

Yes. A system commissioned in late spring captures its remaining months during typically stronger summer production, while one commissioned in late fall captures mostly weaker winter months, so two systems commissioned the same number of months into the year can still see different first-year totals.