Inverters & equipment

Microinverter vs string inverter output tool

Enter your array size and how much of your roof deals with shading. See the real annual output gap between microinverters and a single string inverter on your specific roof.

Your numbers

1 Project details Optional
Shown on your exported report. Leave blank to skip.
2 Your array
From the solar panel calculator or a PVWatts run for your address, before accounting for shading.
3 Shading on your roof
Count any panel that gets shade from a tree, chimney, vent, or neighboring roofline at any point in the day.
How much output the shaded panels themselves lose when shaded.

Try more shading

Drag the slider to change the share of panels affected by shading. The string output, microinverter output, and annual gain update as you move it. The example keeps 11,500 kWh of unshaded output and 40 percent shading severity, the same as the tool above.

15%
String output
10,396 kWh
Micro output
10,810 kWh
Gain with microinverters
414 kWh
0% shaded
0 kWh
5% shaded
138 kWh
10% shaded
276 kWh
15% shaded
414 kWh
25% shaded
690 kWh
40% shaded
1,104 kWh

String loss equals shaded share times 40 percent severity times a 1.6 mismatch multiplier. Micro loss equals shaded share times severity only. Gain is micro output minus string output. The bars show the gain at each shading level.

How it works

Three steps to a clear comparison

Step 1

Start with your unshaded baseline

Pull your array's annual output before shading from the solar panel calculator or a PVWatts run. This is the number both inverter types would produce on a completely clear roof.

Step 2

Be honest about your shading

Walk your roof at different times of day, or check the obstruction loss calculator if you have chimneys, vents, or dormers cutting into panel placement.

Step 3

Weigh the output gain against the cost

Once you see the annual kWh gap, compare it against the price difference in the central vs string inverter cost tool to see which option pays back faster on your roof.

15% of panels shaded: microinverters win back 414 kWh a year

Hover or tap each part of the picture to see what it means.

ARRAY8.00 kWSHADED PANELS15%SHADE SEVERITY40% STRING LOSS9.6%shading hits the stringone weak panel drags all MICRO LOSS6.0%only shaded panels loseeach panel on its own GAINED414 kWh/yrmicro minus string10,810 minus 10,396 With 15% of panels shaded at 40% severity, microinverterskeep 414 kWh more a year than a string inverter. STRING OUTPUT10,396 kWh/yrMICRO OUTPUT10,810 kWh/yrGAIN4.0%

Understanding the output gap

Why shading hurts a string inverter more than you'd expect

Panels wired in series share one current path, and that current gets capped by the weakest panel in the string. If one panel out of ten sits in partial shade, it doesn't just lose its own output. It can drag down the output of the other nine panels connected to it in that string. This amplification effect is why a small amount of shading can cause a disproportionately large drop in a string inverter system's total output. The Department of Energy's inverter systems overview covers this string-wiring behavior in more general terms.

How microinverters and optimizers break that link

Microinverters convert power at each individual panel, so a shaded panel only loses its own output and doesn't pull down its neighbors. Power optimizers work similarly at the DC level, conditioning each panel's output before it reaches a shared string inverter. Both approaches trade the amplified mismatch penalty for a smaller, more predictable loss that scales directly with how much of the array is actually shaded.

When the output gap is too small to matter

On a fully unshaded, single-orientation roof, a string inverter and a microinverter system produce nearly identical annual output. The output gap only widens as shading and mismatch increase, so a roof with no trees, chimneys, or dormers in the way often doesn't justify the added cost of panel-level electronics on output alone. The power optimizer sizing calculator can help if you're weighing a middle option instead of full microinverters, and for a cost-only comparison rather than an output projection, the output calculator with microinverters looks at the same decision from that angle. NREL's PVWatts calculator can model the output difference at a finer level of detail than the estimate here.

Reliability is part of the real comparison too

Output isn't the only factor. Microinverters put more individual components on the roof, which means more potential points of failure over a 25-year system life, though each failure only affects one panel instead of a whole string. String inverters concentrate their electronics in one accessible location, which can make troubleshooting and replacement simpler. The inverter lifespan estimator and inverter warranty value calculator factor these long-term considerations into the decision. The output calculator with microinverters shows how this number plays out in real production.

What to do with this comparison

If your output gain from this tool is small, a string inverter with a good warranty is usually the more cost-effective choice. If the gain is significant, the extra upfront cost of microinverters or optimizers often pays for itself within a few years through the additional energy produced.

Questions

Frequently asked

Only when shading or panel mismatch is present. On a fully unshaded roof, output is nearly identical. On a roof where 15% of panels get partial shade averaging 40% severity, microinverters typically produce about 4% more annual output than a string inverter on the same array.

Panels in a series string share the same current, and that current is capped by the weakest panel in the string. A single shaded panel can pull down the output of every panel connected in series with it, not just its own output.

Yes. On a simple, unshaded roof with one orientation, a string inverter usually costs less upfront and has fewer components on the roof to fail over time, since microinverters put electronics on every panel instead of one central location.

Power optimizers sit between the two approaches. They fix the mismatch problem at the panel level like microinverters do, but still rely on one central string inverter for the actual DC to AC conversion. The power optimizer vs microinverter comparison tool breaks down that tradeoff.