Enter your household loads and desired backup hours. Get a straightforward battery count for a standard single-family home.

Your numbers

1 Project details Optional
Shown on your exported report. Leave blank to skip.
2 Your loads and duration
3 Battery unit and characteristics

Try a different backup time

The same 600 W load and 13.5 kWh battery size at 90 percent depth of discharge and 92 percent round trip efficiency as the tool above. Drag the slider to change the backup hours.

24 hours
Batteries needed
2
Nameplate size
17.39 kWh
Usable energy
14.40 kWh
200 W load
5.80 kWh
400 W load
11.59 kWh
600 W load
17.39 kWh
800 W load
23.19 kWh
1,000 W load
28.99 kWh
1,500 W load
43.48 kWh

Maths: usable energy is the load in kW times the backup hours. Nameplate capacity is usable energy divided by 90 percent depth of discharge times 92 percent round trip efficiency. Battery count rounds the nameplate size up to whole 13.5 kWh batteries. The example load is 600 W, as in the tool above.

How it works

Three steps to your battery count

Step 1

Total your household loads

What matters is which circuits you back up, not your home's total square footage. The critical loads calculator and whole home backup tool both help build this list. Once you have this number, the oversizing for future battery calculator sizes the array around it.

Step 2

Choose your battery unit size

Most residential batteries range from 10 to 13.5 kWh per unit. Check your preferred brand's spec sheet for the exact figure.

Step 3

Confirm your inverter can support the count

Each inverter has a maximum battery pairing limit. The battery inverter pairing tool checks this against your resulting count.

Critical loads need 2 batteries, whole home needs more

Hover or tap each part of the picture to see what it means.

Criticalload600 W Duration24 hours Usableenergy14.4 kWh Nameplate17.4 kWh BATTERIES NEEDED2 WHOLE HOME WITH HVAC4 to 6

Understanding single-family home battery count

Why home size isn't the main driver of battery count

Battery count depends primarily on which loads you choose to back up and for how long, not the square footage of the home itself. A small home backing up its whole panel including HVAC can need more batteries than a large home backing up only critical loads. That said, larger homes do tend to have bigger HVAC systems and more circuits overall, which indirectly correlates with higher battery counts in whole home backup scenarios. The whole home backup tool and critical loads calculator both show how load selection, not size, drives this number.

Why inverter capacity caps your practical battery count

Every inverter model has a maximum number of battery units it can pair with, commonly ranging from 3 to 10 depending on the brand and model, a limit set by the inverter's own charge and discharge current rating rather than the battery itself, as explained in the Department of Energy's inverter basics guide. A calculated battery count that exceeds your inverter's limit means either choosing a different inverter or accepting a smaller battery count and a correspondingly shorter backup duration. The battery inverter pairing tool checks your calculated count against typical inverter limits, and the hybrid inverter sizing calculator in our Inverters & Equipment category covers choosing the inverter itself.

Planning for future load additions

Many installers recommend leaving some headroom in your inverter's rated capacity for likely future additions, such as an electric vehicle charger, a heat pump upgrade, or a pool pump, since retrofitting additional battery capacity later can involve a separate installer visit and higher marginal cost than including it upfront, a planning approach ENERGY STAR's electric-ready home guidance recommends for exactly these future loads. The battery expansion planning tool and oversizing for future battery calculator both address this planning approach directly.

What to do with this number next

Once you have a working battery count, the single vs multi battery cost tool shows how per-unit pricing changes at different battery counts, and the cost per kWh comparison tool compares what different brands charge for the total capacity you need. If you're financing this purchase, the loan payment calculator in our Financing category shows what different battery counts would cost monthly. The hybrid inverter sizing calculator checks whether your inverter can handle this result.

Questions

Frequently asked

A single-family home backing up a 600 watt critical loads circuit for 24 hours needs about 17.4 kWh of nameplate capacity, or 2 batteries at 13.5 kWh each. Whole home backup including HVAC typically pushes this to 4 to 6 batteries instead.

Not directly. Battery count depends on which loads you choose to back up and for how long, not square footage itself, though larger homes often have more circuits and higher-draw equipment like bigger HVAC systems that indirectly push battery count higher.

Yes, each inverter model has a maximum number of battery units it can pair with, commonly 3 to 10 units depending on the brand and model. The battery inverter pairing tool checks this limit against your calculated battery count.

Many installers recommend leaving some inverter capacity headroom for likely future additions, such as an EV charger or a heat pump upgrade, since adding battery capacity later can be more expensive than including it in the initial installation. The battery expansion planning tool and oversizing for future battery calculator both cover this planning approach.