Battery chemistry & storage

Battery energy density comparison tool

Enter the capacity you need. See the estimated weight and volume across six battery chemistries, checked against your own space and weight limits.

Your numbers

1 Project details Optional
Shown on your exported report. Leave blank to skip.
2 Your capacity need
3 Your constraints Optional
1 cubic foot is about 28.3 liters, for reference.

Try a different battery size

Drag the slider to change the battery capacity. The weight for each chemistry updates. Starting point is 10 kWh, the same example as the tool above.

10 kWh
LFP weight
130 lb
LFP volume
25 L
NMC weight
100 lb
LFP
130 lb
NMC
100 lb
Lead acid
668 lb
Sodium-ion
184 lb
Flow (vanadium)
1,102 lb
Saltwater
394 lb

Weight equals capacity in watt-hours divided by gravimetric density, converted to pounds. At 10 kWh LFP weighs 130 lb and takes 25 litres, and NMC weighs 100 lb.

How it works

Three steps to compare density fairly

Step 1

Enter the capacity you need

Every chemistry gets sized to the same target so the comparison is about density, not raw capacity. The chemistry weight comparison is a good next stop for a closer look at just the weight side.

Step 2

Add your actual weight and space limits

Structural weight limits and available footprint rule out options fast. Skip these if you have no hard constraints yet.

Step 3

Cross-check with a specific product's spec sheet

These are typical pack-level figures. The NMC energy density calculator lets you check a real product's measured density against the same benchmarks.

Flow is heaviest by far: 1,102 lb for 10 kWh

Hover or tap each part of the picture to see what it means.

130 lb LFP 100 lb NMC 668 lb Lead acid 184 lb Sodium-ion 1,102 lb Flow 394 lb Saltwater LIGHTEST100 lb NMCHEAVIEST1,102 lbYOUR BUDGET200 lb

Understanding your energy density comparison

Why NMC and LFP lead on density, and why that's not the whole story

NMC and LFP both pack more energy into less weight and space than lead acid, sodium-ion, flow, or saltwater chemistries, largely due to their more energy-dense electrode chemistry, materials work NREL's energy storage research continues to refine on both the cell and pack level. That density advantage comes with tradeoffs elsewhere, covered in the LFP vs NMC cycle life comparison and other chemistry-specific tools throughout this hub.

Why flow and saltwater batteries trail so far behind on density

Flow batteries store energy in liquid electrolyte tanks rather than compact solid electrodes, and saltwater batteries use a lower-density active material by design, both trading raw density for safety, cycle life, or scalability advantages covered in their dedicated comparison tools. Density alone doesn't capture those tradeoffs, though in a genuinely tight space, such as the scenario covered in the battery sizing for apartment balcony solar tool, that density gap can rule out the bulkier chemistries regardless of their other advantages.

Weight versus volume: which one actually constrains your install

A rooftop or wall-mounted install often hits a weight limit before running out of physical space, while a closet or small utility room often hits a space limit first. Check both figures against your real installation, since the same chemistry can pass one test and fail the other depending on the room. The footprint size comparison goes deeper on the space side specifically, and the van life battery sizing calculator covers a build where both weight and volume are tightly constrained at once.

What to check next

Once you've narrowed down chemistries by density, the power density comparison checks a related but different metric: how much output power each chemistry can deliver relative to its size. This same weight-and-space tradeoff shows up in how the DOE's Office of Electricity evaluates storage hardware for site-constrained grid installations.

Questions

Frequently asked

NMC leads common storage chemistries on both weight and volume, needing about 100 pounds and 21 liters to deliver 10 kWh, compared to roughly 130 pounds and 25 liters for LFP. Flow and saltwater batteries sit at the opposite end, often needing several times the weight and volume for the same capacity.

A utility closet, garage corner, or basement often has a fixed footprint before weight ever becomes the limiting factor, especially for bulkier chemistries like flow or saltwater batteries. Checking both weight and volume against your actual install space avoids discovering a fit problem after a battery arrives.

No. Energy density is one factor among cost, cycle life, safety, and climate performance, and a lower-density chemistry can still be the right choice if space and weight aren't limiting factors for your installation. Lead acid, for example, is far less dense than lithium but remains common where upfront cost matters more than footprint.

These are pack-level estimates, including the enclosure, wiring, and battery management system, not the higher cell-level figures often quoted in marketing material. Pack-level numbers are what you'll actually experience installing a finished product.